Other information:
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the IATS connector.
3.
Measure resistance between the IATS terminals 3 and 4.
4.
Check that the resistance is within ...
Specification
Item
Specification
Control type
ON/OFF
Voltage (V)
9 - 16
Control pressure kpa (kgf/cm², psi)
0 - 490.33 (0 - 5.0, 0 - 71.12)
Coil resis ...