Kia Sportage: Heating,Ventilation And Air Conditioning / Specifications
Air Conditioner
Item
|
Specification
|
R 2.0
|
NU
|
THETA
|
Compressor
|
Type
|
DVE16N
|
Oil type & Capacity
|
PAG 30 120 ± 10cc (4.05 ± .33oz.)
|
Pulley type
|
6PK-TYPE
|
Displacement
|
160cc/rev
|
Expansion valve
|
Type
|
Block type
|
Refrigerant
|
Type
|
R-134a, R-1234yf
|
Capacity
|
550 ± 25g (19.4 ± 0.88oz.)
|
Blower Unit
Item
|
Specification
|
Fresh and recirculation
|
Operating method
|
Actuator
|
Blower
|
Type
|
Sirocco
|
Speed step
|
Auto + 8 speed (Automatic), 1-4speed (Manual)
|
Speed control
|
Power mosfet (Automatic), Resistor (Manual)
|
Air filter
|
Type
|
Particle filter
|
Heater and Evaporator Unit
Item
|
Specification
|
Heater
|
Type
|
Pin & Tube type
|
Heating capacity
|
4,700 - 5% kcal/hr
|
Mode operating method
|
Actuator
|
Temperature operating method
|
Actuator
|
Evaporator
|
Temperature control type
|
Evaporator temperature sensor
|
A/C ON/OFF
|
ON : -0.5°C (31.1.8°F)
|
OFF: -1.5°C (29.3°F)
|
Heating capacity
|
4,800 - 5% kcal/hr
|
Items
|
N·m
|
kgf·m
|
lb·ft
|
Compressor
|
Mounting bolt
|
20.0 - 32.95
|
2.04 - 3.36
|
14.75 - 24.30
|
Limiter bolt
|
5.0 - 7.0
|
0.51 - 0.71
|
3.7 - 5.1
|
Clutch bolt
|
9.8 - 14.7
|
1.0 - 1.5
|
7.2 - 10.8
|
Discharge hose - bolt
|
7.8 - 11.8
|
0.8 - 1.2
|
5.8 - 8.7
|
Discharge pipe - bolt
|
Suction hose - bolt
|
Liquid tube & hose - bolt
|
Discharge hose - nut
|
7.8 - 11.8
|
0.8 - 1.2
|
5.8 - 8.7
|
Discharge pipe - nut
|
Suction hose - nut
|
Liquid tube & hose - nut
|
Special Service Tools
Tool Name / Number
Illustration
Description
Disc & hub assembly bolt remover
09977- 3R000
...
Other information:
Special Service Tools
Tool Name / Number
Illustration
Description
RKE Battery Checker
(09954-2P100)
Measuring the RKE battery voltage
Calibration jig for LDWS or LKAS
(09890-3 ...
To defog inside windshield
1. Set the fan speed to the desired position.
2. Select desired temperature.
3. Select the or
position.
4. The outside (fresh) air and air conditioning will be selected automatically.
If the air conditioning and/or outside (fresh) air position are not selected
...