Kia Sportage: Evaporative Emission Control System / Purge Control Solenoid Valve (PCSV) Description and operation
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls
the passage between the canister and the intake manifold. It is a solenoid valve
and is open when the ECM grounds the valve control line. When the passage is
open (PCSV ON), fuel vapor stored in the canister is transferred to the intake
manifold.
Specification
Item
Specification
Coil Resistance (Ω)
22.0 - 26.0 [20°C(68°F)]
...
Circuit Diagram
Terminal Information
Terminal Illustration
Terminal Function
No.
Function
Connected ...
Other information:
Inspection
Check the brake fluid level in the brake fluid reservoir. The level should be
between “MIN” and “MAX” marks on the side of the reservoir.
Use only hydraulic brake fluid conforming to DOT 3 or DOT 4 specification.
Check the brake system for any lea ...
Component Location
1. Panorama sunroof
2. Panorama sunroof switch
3. Panorama sunroof motor & controller
4. Roller blind motor & slave controller
...